Filter Results By:

Products

Applications

Manufacturers

High Voltage

electric power transmission is > 35,000 volts and for safety AC > 1000 and DC > 1,500. AKA: HV

See Also: High Voltage Switching, High Voltage Meters, High Voltage Detectors, High Voltage Programmable Power Supplies, HV


Showing results: 1831 - 1845 of 2464 items found.

  • PXI 2 Amp Multiplexer, Single 8-Channel, 8-Pole

    40-635A-004 - Pickering Interfaces Ltd.

    The 40-635A-004 is a single 8-channel, 8-pole MUX and is part of a range of Multiplexer modules available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC. The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.

  • PXI 2 Amp Multiplexer, Dual 16-Channel, 2-Pole

    40-635A-006 - Pickering Interfaces Ltd.

    The 40-635A-006 is a dual 16-channel, 2-pole MUX and is part of a range of Multiplexer modules available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC. The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.

  • PXI 2 Amp Multiplexer, Quad 4-Channel, 2-Pole

    40-635A-109 - Pickering Interfaces Ltd.

    The 40-635A-109 is a quad 4-channel, 2-pole MUX and is part of a range of Multiplexer modules available in 9 standard density and 9 half density configurations, all using high quality electro-mechanical signal relays allowing each channel to switch current up to 2A and voltage up to 300VDC/250VAC. The module is suitable for signal routing in ATE and data acquisition systems. Connections are made via a front panel 78-way D-type connector.

  • Digital Insulation Mult-Meter

    8005 IN - Standard Electric Works Co., Ltd

    ● Microprocessor controlled.● Four insulation test voltages (DC) : 50V, 100V, 250V, 500V● The maximum insulation measurement range is 200G ohm @500V.● Large LCD (78 × 67mm)● Auto-ranging.● Bar-graph indication.● Backlight function.● REL(Auto-null) function.● Auto AC/DC voltmeter.● Capacitor test.● Auto-test stop & smart hold.● Supplied with high quality test leads.● Safety standard : EN 61010-1 CAT III

  • High-Voltage Power Amplifier / Piezo Driver

    Model 2205 - TREK, INC.

    The Trek Model 2205 is a member of Trek’s 2200-series of high-voltage 40 W amplifiers that offesr high performance at an attractive price. It incorporates DC stability, wide bandwidth, well regulated and controlled AC output signals, full four-quadrant class AB all-solid-state output stages, DC offset adjustment with front panel metering, and autorecovery shutdown to protect the output from being overpowered. The instrument also stage sinks or sources current into reactive or resistive loads throughout the output voltage range which makes it ideal to achieve the accurate output response and high slew rates demanded by reactive loads.

  • Spiral Antenna UHF Trafo

    Techimp HQ S.r.L

    UHF Spiral antenna is a partial discharge sensor designed to receive electromagnetic (EM) emissions from a PD occurring in the monitored asset. It is a broadband antenna with a flat response which makes Spiral antenna suitable in a number of different applications. It has been optimized to operate in a frequency range typical for PD activity and it was designed to provide maximum sensitivity and high gain. Its compact and robust design (passive sensor) makes Spiral antenna the optimal sensor for direct installation on high voltage Transformers. It can be virtually applied in any electrical equipment provided that it has apertures or EM transparent surfaces. Contact our sales department for consulting.

  • Precision DC Power Module, 20V, 50A, 300W

    N6763A - Keysight Technologies

    The Keysight N6763A is a 300W precision DC power module that provides low noise, and precise control and measurements in the milliampere and microampere region with the ability to simultaneously digitize voltage and current, and capture those measurements in an oscilloscope-like data buffer. This module is used in both the small, multiple output 1U high N6700 Low-Profile Modular Power System (for ATE systems) and the multiple output N6705 DC Power Analyzer (for bench testing). GPIB, LAN, USB and LXI compliance are standard. Select from more than 30 different DC power modules ranging in capability from basic to high precision, and in power from 20-500 Watts.

  • PXIe-2527, 32‐Channel, 300 V, 2‐Wire PXI Multiplexer Switch Module

    780587-27 - NI

    32‐Channel, 300 V, 2‐Wire PXI Multiplexer Switch Module—The PXIe‑2527 is a high‐voltage PXI multiplexer switch module that is ideal for medium‑ to high‑density automated test applications. Featuring high-power electromechanical relays, the PXIe‑2527 is the perfect front end for the PXI DMM modules, offering simple channel expansion for a variety of measurements. The PXIe‑2527 supports multiple channel configurations including 64x1 1‑wire, 32x1 2‑wire, and 16x1 4‑wire. It also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.

  • PXI-2527, 32‐Channel, 300 V, 2‐Wire PXI Multiplexer Switch Module

    778572-27 - NI

    32‐Channel, 300 V, 2‐Wire PXI Multiplexer Switch Module—The PXI‑2527 is a high‐voltage PXI multiplexer switch module that is ideal for medium‐ to high‐density automated test applications. Featuring high-power electromechanical relays, the PXI‑2527 is the perfect front end for the PXI DMM modules, offering simple channel expansion for a variety of measurements. The PXI‑2527 supports multiple channel configurations including 64x1 1‑wire, 32x1 2‑wire, and 16x1 4‑wire. It also features onboard relay counting for relay monitoring and deterministic operation with hardware triggers to improve test throughput.

  • Data Acquisition Recorders & Loggers

    B&K Precision Corporation

    B&K Precision offers a full range of data acquisition recorders & loggers for measuring parameters such as voltage, temperature, current, resistance, frequency, and pulse. From high speed recording with deep memory, to long battery life for portability.

  • DC Hipot Testers

    DPW Series - UDEYRAJ ELECTRICALS PRIVATE LIMITED

    These portable testers have been designed to be used in testing high voltage equipment in power engineering. Routine testing of the insulation and leakage is a necessary requirement for surge arresters, cable breakdown testing, capacitor charging and other laboratory use.

  • Programmable Switching Power Supplies

    PeakTech Prüf- und Messtechnik GmbH

    In addition to presets for current and voltage values, time programs with intervals and the number of runs can also be created directly on the device or using the included PC software. For operation with a PC, the switching power supply is equipped with a USB and RS-485 interface. A PC connected to the RS-485 interface enables the control of up to 32 power supplies. A USB interface on the back of the device connects to a Windows PC. The intelligent fan control adjusts the speed of rotation to the respective temperature and output power. The output voltage and current limit can also be set in the open circuit without a connected load. Due to its high reliability and the programming functions, this power supply series is ideal for professional users from industry, control and regulation technology or the electronics laboratory.

  • Non-Contact H.V. Detector

    375 HP - Standard Electric Works Co., Ltd

    ● Protection class : IP65.● 8 voltage settings : 240V, 2kV, 6kV, 11kV, 22kV, 33kV, 132kV, 275kV● Bright LED visual indication● Frequency range: 40~70Hz● Flashlight funcion●Wider angle for voltage detection(120°)●Audible indication● Easy-to-prove method● Self-test function● Power source : 1.5V "C" type battery × 3● High impact nylon casing● Non-contact work by proximity● Compatible with most hot sticks● Lightweight, robust & compact● Suitable for indoor and outdoor use● Easy access to batteries.● Special ranges are available upon request. ● The maximum detection range can be 500kV.● Meets EN 61326-1 CISPR 11 EN 61000-4-2 EN 61000-4-3 EN 61000-4-8

  • sbRIO-9205, Non-Enclosed, ±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module

    784787-01 - NI

    Non-Enclosed, ±10 V, 250 kS/s, 16-Bit, 32-Channel C Series Voltage Input Module - The sbRIO‑9205 performs single-ended or differential analog inputs, with four programmable input ranges for each. It is an effective combination of channel count and speed at a low price for an economical multifunction system. You can choose from four programmable input ranges. To protect against signal transients, the sbRIO‑9205 includes up to 60 V of overvoltage protection between input channels and common (COM). In addition, the sbRIO‑9205 also includes a channel‑to‑earth ground double isolation barrier for safety, noise immunity, and high common-mode voltage range. It is rated for 1,000 Vrms transient overvoltage protection. Non-enclosed modules are designed for OEM applications.

  • Handheld Turns Ratio & Winding Resistance Tester

    TWR-H Series - IBEKO Power AB

    Handheld TWR-H device is DV Power single-phase instrument designed for measuring transformer winding resistance and turns ratio.The instrument has two output DC sources for measuring transformer winding resistance. The first DC source can output up to 2 A DC and is used for injecting current to the transformer’s high voltage winding. The second DC source can output up to 10 A DC and is used for testing the transformer’s low voltage winding. This is especially useful when measuring winding resistance of distribution transformers. These transformers have large turns ratio and therefore a big difference between resistances of high voltage and low voltage windings. Upon the winding resistance test, it is also possible to demagnetize the transformer core. The demagnetization process is completely automatic and safe.Together with the turns ratio, the instrument also measures excitation current and phase shift. This enables detecting transformer core or winding turns failures which cannot be spotted by measuring turns ratio only. The instrument can output test voltage up to 40 V AC for this test, but it can also output a very low test voltage of 1 V AC which is necessary for turns ratio verification of the majority of current transformers.TWR-H is powered by an internal Li-Ion battery. Up to 100 tests can be performed with a fully charged battery.

Get Help